NRM CONST - 528A7-18-707 - Replace Boiler Stack Rome CBOC

Veterans Affairs, Department of

10 days leftSolicitationHVACFacility maintenance
View the official notice at sam.gov

The official notice is always free. Read the full documents there before you bid.

Key facts

Closes
Dec 2, 2026, 10:00 AM ET (10 days left)
Place of work
Location not stated
Notice type
SolicitationA request for offers or bids. This is the notice you respond to.
Solicitation number
36C24227R0008
Office
242-NETWORK CONTRACT OFFICE 02 (36C242)
Posted
Nov 20, 2026
Codes
NAICS 238220 | PSC Z1DA
Contact in the notice
Ryan S Seburn, ryan.seburn@va.gov
Source
SAM.gov Contract Opportunities

What this is

The Department of Veterans Affairs is seeking construction services to replace boiler and generator exhaust stacks at the Rome Community Based Outpatient Clinic. The work is for the clinic at 125 Brookley Road, Rome, NY 13441.

AI summary of the public notice. Check the official notice before you bid.

Report a problem with this summary How we use AI

Full summary

The full summary of this notice is for signed-in users

  • Who can bid
  • Key dates
  • What the work includes
  • How to respond

A free account lets you read 3 full summaries a day and save one search with a daily email. The official notice stays free for everyone.

Similar open bids

  • ID-KOOSKIA NATIONAL FISH- GUTTER RPLCMNT

    Interior, Department of the · Idaho

    Closes tomorrowSolicitation

    Closes Nov 23, 2026, 9:00 AM ET

    The U.S. Fish and Wildlife Service is requesting offers for rain gutter replacement at Kooskia National Fish Hatchery. This is a solicitation, and award will be based on the lowest fair and reasonable price.

  • USAG Pressure Washing

    Dept of Defense · Fort Bragg, North Carolina

    Closes tomorrowCombined synopsis and solicitationHUBZone set-aside

    Closes Nov 23, 2026, 10:00 AM ET

    The U.S. Department of the Army is seeking a contractor for comprehensive pressure washing services. The work covers external facilities, buildings, bridges, and tanks at Fort Bragg and nearby installations in North Carolina.

  • Remplacement des systèmes de ventilation au Centre de formation professionnel des moulins

    Centre de services scolaire des Affluents · Repentigny, Quebec

    Closes tomorrowSolicitationCanada

    Closes Nov 23, 2026, 10:00 AM ET

    Centre de services scolaire des Affluents posted a solicitation titled "Remplacement des systèmes de ventilation au Centre de formation professionnel des moulins". Place: Repentigny, Quebec. Responses are due Nov 23, 2026, 10:00 AM ET. The listing has little detail. Read the official notice for the full scope.

  • Rénovation et mise aux normes des toilettes du Centre municipal

    Municipalité de Sainte-Agathe-de-Lotbinière. · Quebec

    Closes tomorrowSolicitationCanada

    Closes Nov 23, 2026, 11:00 AM ET

    Municipalité de Sainte-Agathe-de-Lotbinière. posted a solicitation titled "Rénovation et mise aux normes des toilettes du Centre municipal". Place: Quebec. Responses are due Nov 23, 2026, 11:00 AM ET. The listing has little detail. Read the official notice for the full scope.

  • CG Station Burlington Replacement Water Heaters

    Homeland Security, Department of · Burlington, Vermont

    Closes tomorrowSolicitation

    Closes Nov 23, 2026, 12:00 PM ET

    The U.S. Coast Guard is soliciting quotes to remove and replace failed domestic hot-water heaters at Coast Guard Station Burlington. The work will restore hot-water service to the galley, berthing spaces, and heads.

More HVAC bids

Recent awards from Veterans Affairs, Department of

Award notices this agency published, as listed by the source.

Original description from the notice

CONTINUATION OF SF 30 BLOCK 14 AMENDMENT DESCRIPTION 0002 AGAINST SOLICITATION NO. 36C24227R0008 1. This amendment answers the following vendor questions: Number of boiler vents: On M-101 (Boiler and Generator Exhaust Plan, Phase II), the new wall penetration/chase is labeled with two 14" I.D. pipes and one 12" I.D. pipe. Keynote 2 calls for a single "new 14" boiler double walled insulated vent stack," and the cutover notes describe that one vent connecting to Boiler #1 and continuing to within two feet of Boiler #2's vent, so one common 14" vent appears to serve both boilers. The solicitation description, however, refers to "two new steel boiler exhaust stacks." Please confirm whether the work is: (a) one 14" double-wall vent common to Boiler #1 and Boiler #2, plus the 12" generator exhaust, or (b) two separate 14" double-wall vents (one per boiler), plus the 12" generator exhaust. If (a), please confirm what the second 14" pipe shown at the penetration represents. Answer: Confirming: it is (b) two separate 14" double-wall vents (one per boiler), plus the 12" generator exhaust. b) Draft control or stack fan: No stack fan, draft inducer, or boiler-outlet draft control appears on the drawings. Section 23 51 00 (paragraph 2.2, Boiler Outlet Dampers and Accessories) refers to automatic draft control specified in Section 23 09 11, but Section 23 09 11 is not included in the solicitation. Please confirm whether: (a) the new boiler vent is intended to operate on natural draft (no fan or draft control required), or (b) a mechanical draft fan and/or barometric or motorized draft control is expected. If so, please issue Section 23 09 11 or identify the required equipment and control sequence. Answer: Confirming: it is (a) the new boiler vent is intended to operate on natural draft (no fan or draft control required). c) Design heating load and operating water temperatures: Please provide the building design heating load (or recent gas and oil usage or meter data), and the normal heating-water supply and return temperatures for the two existing Fulton Vantage boilers. Return-water temperature sets the flue-gas temperature, which governs the vent sizing and draft calculation. Please also confirm whether the two boilers operate as lead/standby (N+1) or are both required at design load. Answer: Replacing the boiler is not part of the contract. Boilers have inducer fans. There is no stack fan or boiler draft controls to be installed. d) Facility designation: Please confirm whether the Rome CBOC is designated mission-critical under VA Physical Security and Resiliency Design requirements, or otherwise required to keep heating on during a utility outage, as this affects the vent design for both fuels. Answer: Rome CBOC is NOT designated as a Critical/Mission Critical facility. CBOCs are generally outpatient facilities rather than hospitals with inpatient, emergency, surgical, or continuity-of-government functions. Therefore, absent a specific VA risk assessment or designation, the Rome CBOC would not ordinarily be assumed to be mission critical. e) Fuel oil and emergency power: Boiler #2 fires #2 fuel oil as a backup fuel. Please confirm (a) whether the vent must be designed for oil firing on Boiler #2 (and on Boiler #1, if applicable), (b) the size and required reserve of the existing #2 oil tank, and (c) whether the boilers and their associated vent or draft equipment are served by emergency power through an automatic transfer switch. Answer: The specified vent material (AL-29-4C) is compatible for operating the boilers on natural gas or #2 oil. This contract does not include altering the existing fuel oil tank, day tank, the boilers, or the generator. We are eliminating the existing exhaust stack and installing a new exhaust stack in a different location to serve the two existing boilers and existing emergency generator. All other terms and conditions remain unchanged.

Source: SAM.gov, General Services Administration (public domain). BidTerrier shows public notices as published and cannot confirm that a notice is complete or current. Details can change, so always check the official notice. Nothing here says whether your business is eligible.