FY26 INSPECTION OF WATER TANK SERVICES (B+OPT4)
Veterans Affairs, Department of
The official notice is always free. Read the full documents there before you bid.
Key facts
- Closes
- Nov 23, 2026, 12:00 PM ET (closes tomorrow)
- Place of work
- Albany, New York
- Notice type
- Combined synopsis and solicitationA short announcement and the request for offers in one notice.
- Set-aside
- Service-disabled veteran-owned small business set-asideA set-aside limits who may compete. The notice states the exact rules.
- Solicitation number
- 36C24226Q0565
- Office
- 242-NETWORK CONTRACT OFFICE 02 (36C242)
- Posted
- Nov 20, 2026
- Codes
- NAICS 561210 | PSC Z2NE
- Contact in the notice
- Clifford S. Harrison, clifford.harrison@va.gov
- Source
- SAM.gov Contract Opportunities
What this is
The Department of Veterans Affairs is seeking inspection and cleaning services for water tanks, along with tank lining services. This is a combined synopsis and solicitation, meaning it serves as both an announcement and a request for quotes. The services are for the Stratton VA Medical Center in Albany, NY.
AI summary of the public notice. Check the official notice before you bid.
Full summary
The full summary of this notice is for signed-in users
- Who can bid
- Key dates
- What the work includes
- How to respond
- Requirements to watch for
- Size or quantity stated
A free account lets you read 3 full summaries a day and save one search with a daily email. The official notice stays free for everyone.
Similar open bids
Project # 528A6-26-607 Replace Flooring for Rm. 140 B76 | Bath VAMC
Veterans Affairs, Department of · New York
2 days leftSolicitationCloses Nov 24, 2026, 11:00 AM ET
The Department of Veterans Affairs is preparing a solicitation for construction work to replace flooring in Rooms 140 and 140A of Building 76 at the Bath, NY VA Medical Center. The project also includes electrical work to support X-ray equipment. This is a presolicitation notice, and the solicitation is expected to be posted on or about October 28, 2026.
Brooklyn Upgrade Life Safety/Critical Branch Electrical Distribution Construction
Veterans Affairs, Department of · Brooklyn, New York
2 days leftSolicitationSmall business set-asideCloses Nov 24, 2026, 3:00 PM ET
The Department of Veterans Affairs is soliciting construction work to upgrade life safety and critical branch electrical distribution systems. The project is at the Brooklyn VA Medical Center in Brooklyn, New York. Amendment 0005 says the bids were canceled before bid opening.
REMOVE AND REPAIR TWO HIGH VELOCITY AIR HANDLING UNITS
Dept of Defense · New York
3 days leftCombined synopsis and solicitationSmall business set-asideCloses Nov 25, 2026, 1:00 PM ET
The Department of the Army is seeking labor, materials, parts and equipment to remove and replace two high velocity air handling units. The work is at Watervliet Arsenal, including Building 36, under Statement of Work #26PW056.
BG-426M Brooklyn Street Tree Planting FY27 - CBs 6, 13
Parks and Recreation · New York City, New York
5 days leftSolicitationCloses Nov 27, 2026, 10:30 AM ET
The New York City Parks and Recreation agency is soliciting bids for Brooklyn street tree planting under project BG-426M, FY27, in Community Boards 6 and 13. Bid submissions must be made through NYC PASSPort.
SMD-Requirement Contract for Installation of V/C Floor Tile in Apartments- Development Name, Located in Manhattan Neighborhood (MN08), and (MN09), Manhattan.
Housing Authority · New York City, New York
5 days leftSolicitationCloses Nov 27, 2026, 2:00 PM ET
The Housing Authority, identified as NYCHA, is seeking contractors to install vinyl composition floor tile in apartments at seven Manhattan developments. This solicitation covers a series of seven requirement contracts, with a possible award limit for each contractor.
Recent awards from Veterans Affairs, Department of
Award notices this agency published, as listed by the source.
- Veterans Affairs, Department of · awarded Nov 22, 2026 · US$60,498 · to VALCORP ENTERPRISES LLC Haltom City TX 76117 USA
- Veterans Affairs, Department of · awarded Nov 20, 2026 · US$49,479 · to NOVOCURE INC PORTSMOUTH 03801 NHB
- Veterans Affairs, Department of · awarded Nov 20, 2026 · US$34,000 · to Edwards Lifesciences LLC IRVINE 92614
- Veterans Affairs, Department of · awarded Nov 20, 2026 · US$45,865 · to WRIGHT & FILIPPIS, LLC ROCHESTER HILLS 48309
Original description from the notice
Combined Synopsis-Solicitation for Commercial Products and Commercial Services Description This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2026-01 (eff. 03/13/2026). This solicitation is set-aside for Service Disable Veteran Owned Small Business. The associated North American Industrial Classification System (NAICS) code for this procurement is 561210 Facilities Support services, with a small business size standard of 47.0 Size Standards in Millions of dollars. FSC/PSC is Z2NE Repair or Alteration of Water Supply Facilities. The Stratton VA Medical Center located at 113 Holland Ave, Albany, NY 12208 is seeking purchase inspection and cleaning services for Tank Lining of 14th-floor Water Tanks. All interested companies shall provide quotations for the following: Supplies/Services BASE: 12/15/2026 11/30/2027 CLIN Description of Goods or Service Quantity Units Estimated Unit Price TOTAL 0001 Inspect and clean two pressurized potable-water tanks, including file review, external/internal visual inspection, UTT, liner testing, confined-space entry/rescue, cleaning, and final report. 1 JB 0002 Tank No. 1 surface preparation, lining, testing, disinfection, and return-to-service documentation. 1 JB 0003 Tank No. 2 surface preparation, lining, testing, disinfection, and return-to-service documentation. 1 JB BASE YEAR TOTAL: $ Option Year 1: 12/01/2027 11/30/2028 1001 Inspect and clean two pressurized potable-water tanks, including file review, external/internal visual inspection, UTT, liner testing, confined-space entry/rescue, cleaning, and final report.inspection, UTT, liner testing, confined-space entry/rescue, cleaning, and final report. 1 JB 1002 Tank No. 1 surface preparation, lining, testing, disinfection, and return-to-service documentation. 1 JB 1003 Tank No. 2 surface preparation, lining, testing, disinfection, and return-to-service documentation. 1 JB OPTION YEAR 1: $ Option Year 2: 12/01/2028 11/30/2029 2001 Inspect and clean two pressurized potable-water tanks, including file review, external/internal visual inspection, UTT, liner testing, confined-space entry/rescue, cleaning, and final report. 1 JB 2002 Tank No. 1 surface preparation, lining, testing, disinfection, and return-to-service documentation. 1 JB 2003 Tank No. 2 surface preparation, lining, testing, disinfection, and return-to-service documentation. 1 JB OPTION YEAR 2: $ Option Year 3: 12/01/2029 11/30/2030 3001 Inspect and clean two pressurized potable-water tanks, including file review, external/internal visual inspection, UTT, liner testing, confined-space entry/rescue, cleaning, and final report. 1 JB 3002 Tank No. 1 surface preparation, lining, testing, disinfection, and return-to-service documentation. 1 JB 3003 Tank No. 2 surface preparation, lining, testing, disinfection, and return-to-service documentation. 1 JB OPTION YEAR 3:$ Option Year 4: 12/01/2030 11/30/2031 4001 Inspect and clean two pressurized potable-water tanks, including file review, external/internal visual inspection, UTT, liner testing, confined-space entry/rescue, cleaning, and final report. 1 JB 4002 Tank No. 1 surface preparation, lining, testing, disinfection, and return-to-service documentation. 1 JB 4003 Tank No. 2 surface preparation, lining, testing, disinfection, and return-to-service documentation. 1 JB OPTION YEAR 4: $ COMPLETE TOTAL: $ STATEMENT OF WORK Inspection/Cleaning and Tank Lining of 14th-floor Water Tanks Stratton VAMC, Albany, NY Introduction Stratton VAMC s mission is to provide world-class healthcare for veterans in the capital region and upstate New York. Background /Objective The Stratton VA Medical Center in Albany, New York, is currently seeking a vendor for the inspection and cleaning of two 25,000-gallon domestic cold water storage tanks located on the 14th floor of the Medical Center. These tanks supply the Medical Center's high loop, floors 5 through 14, with potable domestic water. These tanks also provide redundancy for the fire protection system throughout the building. It is the intent of this contract that the U-1 form (Manufacturer's Data Report for Pressure Vessels) be completed and submitted as required by the provisions of the ASME Boiler and Pressure Vessel Code Rules, Section VII, Division 1 Place of Performance Stratton VAMC, Albany, NY; Bldg. 1, 14th floor. Period of Performance Work will take place Monday-Friday. 7 AM to 4 PM Scope of Work The water storage tanks were installed in 1951 and cleaned/inspected in 2024. Tanks are sound and have not caused any issues, such as leaks or corrosion. They are housed inside on the 14th floor and set horizontally off the ground on a concrete cradle. The tanks are supplied with domestic water from the sub-basement via pumps that convey City of Albany municipal water from the street to the tanks. The tanks have a level float system for operational control. Additionally, the tanks are ASME-pressurized vessels, with compressed house air at the top of each tank, regulated to approximately 18 psi. Specific Tasks cleaning and inspection- Contractor will furnish all parts and labor to accomplish the task of File Review: Perform a review of the available equipment files reflecting original design, OEM construction drawings, repair documentation, and inspection records. The file review aims to fully assess the equipment's operational conditions and history. Contractor will furnish all parts and labor to perform an external visual inspection (VT) utilizing trained engineering personnel competent in tank design and damage mechanisms. Inspections shall include, but are not limited to, the shell, welds, heads, nozzles, appurtenances, relief protection, foundation, and coatings. Contractor will furnish all parts and labor to perform a Non-Destructive Testing inspection utilizing ultrasonic thickness testing (UTT) on the external shell as required. This work shall be performed by trained personnel meeting the requirements of the American Society of Non-Destructive Testing SNT-TC-1A. Contractor will furnish all parts and labor to perform an internal (VT) inspection, liner thickness measurements, and spark testing of the glass liner, which shall be provided by a field service technician. Holiday testing will comply with Standard Practice for Discontinuity (Holiday) Testing of Nonconductive Protective Coating on Metallic Substrates, following ANSVAWWA D103-09 Section 12 by reference to the American Society for Testing and Materials (ASTM D1562-01) and STI SP001. Contractor will furnish all parts and labor to ensure tanks are clean and free of any debris before putting tanks back in service. Contractor will furnish all parts and labor to perform an evaluation, which includes an executive summary that outlines any conditions that inhibit the proper use and functionality of the equipment being inspected. And provides a comprehensive report with pictures and all documentation ascertained before, during, and after the inspections. The report should include, but not be limited to, the following: UTT data and thickness measurement location (TML) map Graphical representation of shell thickness data Calculated minimum thickness Wastage rates (if previous data is provided) Remaining life expectancies (if previous data is provided) Repair recommendations with criticality ranking Inspection pictures Future inspection intervals Contractor will follow all OSHA confined space operating procedures, also having a confined space permit posted at the manway. The contractor will also provide a confined space rescue. Tanks should only be entered after air monitoring with a calibrated meter. Air monitoring must be continuous throughout the inspection. Specific Tasks: Lining of the Tanks- Contractor will furnish all parts and labor to accomplish the task of File Review: Perform a review of the available equipment files reflecting original design, OEM construction drawings, repair documentation, and inspection records. The file review aims to fully assess the equipment's operational conditions and history. Contractor will furnish all parts and labor to perform an external visual inspection (VT) utilizing trained engineering personnel competent in tank design and damage mechanisms. Inspections shall include, but are not limited to, the shell, welds, heads, nozzles, appurtenances, relief protection, foundation, and coatings Contractor will use NSF/ANSI 61 or 600 approved potable water-safe coatings or membranes, such as epoxy, polyurethane, or flexible PVC liners. Linings must be impermeable, corrosion-resistant, chemically resistant, and durable to protect steel or concrete substrates. The contractor will follow all OSHA confined space operating procedures and will have a confined space permit posted at the manway. The contractor will also provide a confined space rescue. Tanks should only be entered after air monitoring with a calibrated meter. Air monitoring must be continuous throughout the inspection. Interior of the tank to be blasted to a SP-10 (near white metal) to prepare for the tank lining Tank to be coated with 25 35 mils of ACOR S-16 two-part epoxy Delivery Schedule or Deliverables Contractor will deliver the finished report no later than 10 days after completion of testing. The report will be delivered to the COR. Non-Compliance- The Contracting Officer or his/her designee will notify the Contractor of any noncompliance with the foregoing provisions and the action to be taken. The Contractor shall, after receipt of such notice, immediately correct the conditions to which attention has been directed. Such notice, when served on the Contractor or his/her representative at the site of the work, shall be deemed sufficient for the purpose aforesaid. If the Contractor fails or refuses to comply promptly, the Contracting Officer may issue an order stopping all and any part of the work and hold the Contractor in default. Government Tasks- VA personnel will empty tanks one at a time for inspection, cleaning, and lining. VA personnel will deenergize pumps. VA personnel will close all appropriate valves. VA personnel will follow all steps to properly Lock Out/Tag Out (LOTO) all necessary valves, pumps, and equipment. Inspection- Upon completion of the testing/cleaning service, the COR/POC will perform the inspection in the presence of the contractor personnel, prior to the contractor personnel leaving the facility. This inspection will ensure that all equipment is returned to full operational condition. No invoices will be processed for payment until the POC inspection is complete. Other Related Services (Not Included in the Scope of Work) Any services not expressly stated in this statement of work are not authorized. Services such as inspection, Original Equipment Manufacturer (OEM) required maintenance, or other maintenance and repair vital to the continued functioning of the systems may be added only after written modification from the contracting officer, unless they are included in the requested services. No person, including the COR or any other VA personnel, is authorized to request that the contractor perform additional work. Any additional services performed that are not authorized by the contracting officer will be considered inclusive. The contract period of performance is: Period of Performance: Base period and four option periods. Exact dates will be established at award. Work hours are Monday through Friday, 7:00 a.m. to 4:00 p.m., excluding Federal holidays, unless otherwise approved in writing. Place of Performance: Stratton VA Medical Center, 113 Holland Avenue, Building 1, 14th Floor, Albany, New York 12208, United States. Place of Performance/Place of Delivery Address: Stratton VAMC, Albany, NY; Bldg. 1, 14th floor. Postal Code: 12208 Country: UNITED STATES The full text of FAR provisions or clauses may be accessed electronically at https://www.acquisition.gov/browse/index/far. The following solicitation provisions and clause apply to this acquisition: FAR 52.212-1, Instructions to Offerors Commercial Products and Commercial Services The electronic files should be in Portable Document Format (PDF) and named as follows: Vendor Name 36C24226Q0565 FY27- INSPECTION OF WATER TANK SERVICES If file size necessitates breaking a section into more than one file, please append File X of X to the end of the file name. All PDF files should be labeled to be considered responsive, the offeror must fill out all applicable areas of the solicitation, as well as any additional requirements/attachments listed below: Part I Technical Capability (Factor 1) (2 copies) Please see the evaluations, this is what you will be evaluated on. Part II - Past Performance, (Factor 2) (2 copies) Please see the evaluations, this is what you will be evaluated on. Part III Pricing (Factor 3) (1 copies) Completed and signed VAAR 852.219-75 certificate. Active SAM registration and all required representations. Completed pricing for every base and option CLIN. The NCO2 Contracting Department requests two (2) Copies of your proposal: one unredacted and one redacted. The redacted copy must have all of your company s information redacted such as Company name, phone numbers, e-mail addresses and any information that can identify your company. When you provided any certifications please redact the person s name and company information as well. This does not apply to the attachments, but the 852.219-75 Limitations on Subcontracting - Compliance for Services and Construction must be completed by all vendors. Failure to follow this request will render your quote nonresponsive. All quotes shall be sent to the Department of Veterans Affairs, Network Contracting Office (NCO) 2 via email to the Contract Officer Clifford S. Harrison at Clifford.Harrison@va.gov by December 4th, 2026, at 12:00PM EST. FAR 52.216-1 Type of Contract APR 1984 (DEVIATION NOV 2025) FAR 52.219-1 Small Business Program Representations (FEB 2024) (DEVIATION NOV 2025) FAR 52.252-1 Solicitation Provisions Incorporated by Reference (FEB 1998) FAR 52.252-5 Authorized Deviations in Provisions (NOV 2020) FAR 52.203-18 Prohibition on Contracting with Entities that Require Certain Internal Confidentiality Agreements or Statements-Representation (JAN 2017) FAR 52.204-7 System for Award Management Registration NOV 2024 (DEVIATION NOV 2025) 852.215-72 Notice of Intent to Re-solicit (OCT 2019) Award will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of RFO FAR 12. FAR 52.212-2 Evaluation-Commercial Products and Commercial Services: In accordance with RFO FAR 12.201-1 and FAR 12.201-2 when appropriate, the contracting officer may (1) Insert the provision at 52.212-2, Evaluation-Commercial Products and Commercial Services, in solicitations for commercial products or commercial services. The following are the decision factors: The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers; Technical Capability Technical Proficiency Contractor Experience Key Personnel Certification OSHA 10-Hour or OSHA 30-Hour Past Performance Price Evaluation Approach. The Government reserves the right to consider a quotation other than the lowest price that provides additional benefit(s). The Government reserves the right to select a quotation that provides benefit to the Government that exceeds the minimum requirements of the solicitation but is not required to do so. Each response must meet the minimum requirements of the solicitation. The Government is not requesting or accepting alternate quotations. Failure to provide the information requested may result in being found non-responsive. The evaluation will consider the following: Evaluation factors. The Government will award a contract resulting from this solicitation to the Offeror responsible whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. For requests for proposals, state: Evaluation factors other than price when combined are more important than price. Technical Capability: Technical capability is defined as an offeror s ability to satisfy the solicitation s requirements, providing the highest quality service to the specified facilities. The Contractor shall provide a maximum 15-page capability statement demonstrating it has trained personnel, equipment, and working experience and ability to meet all the requirements of the Statement of Work (SOW). TECHNICAL PROFICIENCY: The offer shall submit a proposal that verifies it is a firm that specializes in the INSPECTION OF WATER TANKS SERVICES. The proposal must be comprehensive and demonstrate an understanding of the requirements, not a copy-and-paste of the Statement of Work requirements. It shall outline the contractor s ability to perform the services adequately and satisfactorily in accordance with the Statement of Work (SOW) and the extent to which potential risks are identified and mitigated. Contractor Experience: The offeror/prime vendor shall show three (3) instances under the prime vendor company of past-experience similar in nature, scope, complexity, difficulty, and size to that which will be supplied under the prospective contract contemplated by this solicitation. The experience shall reflect no less than three (3) years of service. KEY PERSONNEL: The prime vendor shall identify key personnel and provide resumes for them. The contractor must specify whether subcontractors will be used; if so, provide the pertinent points of contact (POCs) for each subcontractor and describe their placement within the management hierarchy. CERTIFICATION: The prime vendor must provide STI SP-001 AST inspector & API 510 pressure vessel inspector Certification to Qualify for This Requirement. An OSHA Certification will also need to be produced such as: OSHA 10-Hour or OSHA 30-Hour. Past Performance: The prime contractor must provide three references under their company for a contract of similar scope and magnitude to be evaluated. Relevant past performance information shall include key personnel who have relevant experience, predecessor companies, and subcontractors who will perform major or critical elements of this solicitation. The contractors Past Performance shall also be reviewed in PPIRs; Individuals with no past performance shall receive a neutral rating for this evaluation factor. Price: The government will evaluate offers for award purposes based on the pricing for the total requirement. Offers for partial requirements will not be evaluated and will be deemed non-responsive upon receipt. (b) Options. The Government will evaluate offers for award purposes by adding the total price for all options to the total price for the basic requirement. The Government may determine that an offer is unacceptable if the option prices are significantly unbalanced. Evaluation of options shall not obligate the Government to exercise the option(s). Offerors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://sam.gov/. FAR 52.212-4, Contract Terms and Conditions Comm
Source: SAM.gov, General Services Administration (public domain). BidTerrier shows public notices as published and cannot confirm that a notice is complete or current. Details can change, so always check the official notice. Nothing here says whether your business is eligible.